Noble – Data Log Hydraulic Tuning of Excavators


Jon Noble – Health Safety and Training Manager, Glencore – Clermont Open Cut Mine

The Problem

In February 2017 a Coal Mine Worker (CMW) was injured when a hydraulic hose fitting failed under pressure during the use of a hydraulic flow meter. The CMW was positioned inside the pump room and was undertaking the task of a hydraulic tune up. The task requires a calibrated flow meter to be installed in line with the main hydraulic pump system to read the hydraulic flow and pressure the machine is producing. The operator of the flow meter is required to manually adjust the flow meter by hand and watch the pressure and flows on the meter, making it impossible to be out of the line of fire. On the day of the incident a hydraulic fitting failed at the flow meter under 50bar of pressure and shot back contacting the maintainer in the knee luckily only causing minor bruising. During testing procedures the maximum pressure ranges up to 300bar.

The Solution

The implementation of a data logging system that reduces the need to have a person inside the pump room during hydraulic testing. There are two pumps to each main pump. Each pump can now be “turned on” remotely via an electronic remote control. The first individual pump can be cycled and loaded through all curves required to satisfy testing and the change to test, then the second pump can be tested via the flick of a switch. Load to the pumps is applied proportionally through a remote control lever on the test box remote and the pump performance can be seen by the operator outside of the pump room. If adjustments need to be made to the pump regulators the pump is destroked to minimum flow and
to standby pressures using the remote control lever. Once the adjustments have been made the operator can once again remove themselves from the high pressure hose area inside the pump room and return outside and complete the tests again.

You may also like

Coplin - ACArP 26070 Industrialisation of Proof of Concept Wall flow DoC/DPf System
Nick Coplin – General Manager, Engineering Services, Orbital Australia Pty Ltd ABSTRACT Australian Coal Association ...
Clarkson - What else is in a Goaf?
Dr Fiona Clarkson – Research Scientist, Simtars ABSTRACT Mines routinely monitor the gas profiles in their goafs ...
Tyrrell - ACARP - What We have Achieved and What are our Priorities for the Future
Patrick Tyrrell – Australian Coal Industry Research Program ABSTRACT ACARP assists the Australian coal industry to ...
De Kock - Collision Awareness - Capability of Underground Mine Vehicle Proximity Detection Systems
André De Kock – Research Manager, Simtars ABSTRACT One of the major hazards in an underground coal mine is the ...
Burgess-Limerick - Proximity Advisory System Interface Design
Prof. Robin Burgess-Limerick – Professor of Human Factors, Minerals Industry Safety and Health Centre, The ...
Worland - Approaches to Control Worker Dust Exposure During Maintenance Activities Where Compressed Air is Used to “Clean” Equipment
Simon Worland – Occupational Hygienist ABSTRACT Use of compressed air to blow out or “clean” electrical cabinets is ...
Djukic - Dust Exposures in Queensland Surface Coal Mines: 2001 – 2017
Fritz Djukic – Inspector of Mines (Occupational Hygiene), Department of Natural Resources, Mines & Energy ...
LaBranche - Improving Respirable Coal Dust Exposure Monitoring and Control - ACARP Project C26048
Nikky LaBranche – Principal Mining Engineer, Simtars ABSTRACT Since the first case of CWP in over twenty years was ...
Hedges/Champion - Tests and Processes for Systems of Work
Steve Hedges – SVP Operations David Champion – Safety Manager, Millennium Mine, Peabody ABSTRACT In early 2016, ...
Smith - Looking Back to Develop a Pathway Forward - Using Industry Data
Lionel Smith – Regional Inspector of Mines, Department of Natural Resources, Mines and Energy ABSTRACT The mining ...

Page 4 of 10